logo

उत्पादों का विवरण

Created with Pixso. घर Created with Pixso. उत्पादों Created with Pixso.
स्थिर मीटर परीक्षण बेंच
Created with Pixso.

0.01 Accuracy Three-Phase Meter Test Bench

0.01 Accuracy Three-Phase Meter Test Bench

ब्रांड नाम: GENY
मॉडल संख्या: Yc1893d
एमओक्यू: 1 टुकड़ा
कीमत: बातचीत योग्य
भुगतान की शर्तें: एल/सी, टी/टी, डी/पी
आपूर्ति करने की क्षमता: 100/वर्ष
विस्तार से जानकारी
उत्पत्ति के प्लेस:
चीन
प्रमाणन:
ISO, CE
दस्तावेज:
सटीकता वर्ग:
0.01
एक साथ संदर्भ-मीटर स्थिति:
3/6 (अनुरोध पर अधिकतम 12)
चरण शिफ्ट रेंज:
0 ° - 360 °
परिचालन तापमान:
20 डिग्री सेल्सियस ±5 डिग्री सेल्सियस
संचालन आर्द्रता:
50% आरएच ±15% आरएच
पैकेजिंग विवरण:
प्लाईवुड मामले
आपूर्ति की क्षमता:
100/वर्ष
प्रमुखता देना:

high accuracy three-phase meter test bench

,

stationary meter test bench with warranty

,

three-phase meter test bench 0.01 precision

उत्पाद का वर्णन
0.01 Accuracy Three-Phase Meter Test Bench
Special Functions
  • Forward and reverse active energy testing
  • Forward and reverse reactive energy error testing
  • SW-5D bridge wiring method for basic error testing of programmable energy meters
  • Communication testing, remote meter reading, and computer time synchronization
  • Meter constant (pulse constant) verification, including:
    • Pulse counting method
    • Time measurement method
    • Stopwatch method
  • Time-of-use (TOU) testing, maximum demand testing, and display value error verification
  • Influence tests, including:
    • Voltage unbalance test
    • High-order harmonic test
  • Disturbance tests, including:
    • Voltage dip test
    • Short-duration power interruption test
General Functions
  • Measurement functions: Active power, reactive power, active energy, reactive energy, starting test, and creep test for three-phase energy meters
  • Accuracy evaluation: Basic error, mean error, standard deviation, and 24-hour stability test for high-accuracy calibration
  • Voltage and current output: Adjustable frequency and harmonic generation (1st-64th order), supporting phase sequence influence testing
  • Multi-meter calibration: Simultaneous calibration of energy meters with different accuracy classes and phase sequences; automatic identification of meter constants
  • Safety protection: Current open-circuit protection and voltage short-circuit protection to ensure reliable calibration operation
  • Operating modes: Automatic and manual calibration modes
  • Data processing: Automatic error calculation, data processing, data storage, and PC-based online output
  • Interfaces: Optical and pulse input channels, flexible configuration, supporting multi-channel meter input
  • Power source system: Modular high-power three-phase source, special power design with high efficiency and low loss
  • Standards compliance: Fully compliant with IEC 62053, IEC 597, and R46 requirements for energy meter calibration systems
  • Mechanical structure: Robust, practical, and professional industrial design for laboratory applications
0.01 Accuracy Three-Phase Meter Test Bench 0 0.01 Accuracy Three-Phase Meter Test Bench 1